28
5. Operation and Configuration
2. Enter the desired holding temperature and confirm by
pressing the green button.
The holding temperature was successfully edited. All the other
parameters shown in the firing curve can be changed / edited in the
same way.
Browsing the programs
If a program has been selected, the neighbouring programs can be
accessed by pressing the [Arrow] buttons.
5.2.3 Program screen / Editing programs
If a program has been selected, the program screen is displayed. The firing programs can be changed or edited in this
screen.
For Ivoclar Vivadent programs, the write-protection must be deactivated first before any parameters can be
changed.
The following information is displayed:
1. Information bar
Program designation
Current furnace temperature
2. Firing curve
Closing time, holding time
Temperature increase rate, holding temperature,
long-term cooling
Vacuum on, vacuum off
3. Program options
In addition to the parameters shown in the firing curve,
several other options are available that can be activated by pressing the [Options] button. The icons in the grid show the
activated options.
Editing parameters
Parameters are entered or edited in two steps.
Example: Setting the holding temperature
1. Press the [T] button.