Page #15 background imageLoading...
Page #15 background image
15
IVT 495 TWIN 9518799
Setting the room sensor influence
(This requires a room sensor, which is an
accessory.)
A room sensor allows you to influence the heat
curve. For each degree of deviation from the
required room temperature, the heat curve is
corrected with the set influence.
Example: If the room is one degree too warm and
the set value is 5, the flow temperature is reduced
by 5ºC.
1. Press the right button once and the text Set the
house heating here appears on the display.
2. Press the right button once again and the text
Heat more/less range 0-10 appears on the
display.
3. Turn the dial until Setting room temp
influence appears on the display.
4. Press the right button once and the text Set
value: appears on the display.
5. Press the right button (Adjust), the display
now shows the previously set value. Turn the
dial until the required value has been set.
6. Press the right button when the required value
has been set (Save). The value is now saved.
Press the left button to return to the main
menu.
Set the house
heating here 1
Heat more/less
range 0-10 1.1
Setting room
temp influence 1.11
Set value: 5
Return Adjust
Cancel 5 Save
Room sensor influence