Page #24 background imageLoading...
Page #24 background image
24
IVT 495 TWIN 9518799
Setting the additional heat, cont.
Set the house
heating here 1
Settings for
addition 8
Quickstart add. heat
temperature 8.16
Set value: 5,0
Return Adjust
IIIIIIII I I I I I I
Cancel 5,0 Save
Quickstart additional heat
The heat pump normally delivers the entire
house’s supply down to an outdoor temperature of
+5°C. (This should be seen as a guide and differs
from case to case depending on the hot water
consumption, size of the house, etc.)
When the outdoor temperature falls below the
temperature set in 8.16 the additional heating
delay is decreased to quickly meet the heating
requirement. If you feel it takes too long before the
duration hot water becomes warm you can
increase this temperature. Remember that a higher
value increases power consumption.
1. Press the right button once and the text Set the
house heating here appears on the display.
2. Turn the dial until the text Settings for
addition appears.
3. Press the right button once and the text Quick-
start add. heat temperature appears on the
display.
4. Press the right button again and the text Set
value: appears on the display.
5. Press the right button (Adjust). The previously
set value is shown on the display. Turn the dial
to change the value.
6. Press the right button (Save) once the required
temperature has been set. The value is now
saved. Press the left button a few times to
return to the main menu.
USER

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IVT 495 TWIN and is the answer not in the manual?