Settings
6 720 645 504 (2011/04) en
63
B Go back one step with .
B Select Saving alternative:
Return without saving
Program 1
Program 2
The set changes are saved as a selected program or
not at all.
B To adjust the normal temperature, proceed to menu
Room temperature normal.
B To adjust the exceptional temperature, proceed to
menu Room temperature exception.
Room temperature program when there is a room
sensor:
> Room temperature program
>> Active program
If a program is selected, the following (if the menu
button is turned) is displayed:
>> View/edit active program
>> Room temperature normal
B Set the desired set point for the room temperature.
>> Room temperature exception
B Set the temperature that should apply as exceptional
temperature in the program.
The menu is displayed only if Program 1or Program
2has been selected.
>> Copy to all heating circuits
B Select Yes to have the same control for all installed
circuits.
The menu is displayed only under Circuit 1.
>> Air handling unit in circuit
B Select Yes when such a unit exists in the circuit.
Room temperature program when there is no room
sensor:
> Room temperature program
>> Active program
>> View/edit active program
The same as when there is a room sensor, see above.
>> Room temperature normal
B Set the measured value in the room.
The indicated value is used by temperature programs
to calculate the difference between normal and
exceptional temperature.
>> Temperature increase/decrease
B Use this function to adjust the room temperature so
that the normal room temperature (see the previous
menu) becomes the desired temperature.
B Use this function to simply increase or decrease the
heat when there are no room sensors.
– gives approx. 1 °C lower room temperature.
– gives approx. 0.5 °C lower room temperature.
+ gives approx. 0.5 °C higher room temperature.
++ gives approx. 1 °C higher room temperature.
Factory setting 20.0 °C
Lowest value 10.0 °C
Highest value 35.0 °C
Tab. 64 Room temperature, normal
Factory setting 17.0 °C
Lowest value 10.0 °C
Highest value 30.0 °C
Tab. 65 Room temperature, exception
Factory setting No
Alternative No/Yes
Tab. 66 All circuits
Factory setting No
Alternative No/Yes
Tab. 67 Air handling unit
In the event of mixed additional heat with
setting Op/Cl in Connected to output type,
Mixing valve running time and P constant
must be set differently from the factory
values ( Chapter 16.7).
Factory setting 20.0 °C
Lowest value 10.0 °C
Highest value 35.0 °C
Tab. 68 Room temperature, normal
Factory setting =
Alternative – , , =, +, ++
Tab. 69 Room temperature increase/decrease