Settings
6 720 645 504 (2011/04) en
70
>> Start temperature T3 economy mode
>> Stop temperature T8 economy mode
>> Start temperature T3 comfort mode
>> Stop temperature T8 comfort mode
> Hot water settings HP 2
>> Hot water production
B Select Yes if heat pump 2 should take part in the hot
water production. Heat pump 1 must make hot water.
Heat pump 2 can work with another hot water heater. In
this case, E42.T3 is used for start and stop. This sensor
must then be connected.
At Yes a further external 3-way valve is required.
B Set values for heat pump 2 for Economy and Comfort.
Factory settings are 10K lower then for heat pump 1.
> Block heating during hot water demand
B Yes should always be used.
> Maximum temperature difference circuit 1
B Indicate how many degrees lower than the set point
value for the flow temperature - half the hysteresis
may become before the heating priority kicks in.
Heat pump 2 stops producing hot water and switches
over to heating. The set point value for the flow
temperature is reduced with the set temperature
difference. This setting has no relevance when only
heat pump 1 produces hot water.
> Hot water circulation (accessory)
A special circulation pump for hot water, E41.G6, can be
installed. It is subject to time control, i.e., it can be
activated during parts of the day. Due to the circulation,
the hot water reaches the tapping place faster.
>> Hot water circulation pump active
B Select Yes if a circulation pump is installed.
Then time settings can be done.
Yes sets the hot water mode to Comfort
automatically and the menu Hot water mode is not
shown.
Factory setting 47 °C
Lowest value 20 °C
Highest value 57 °C
Tab. 100 Start temperature T3 economy mode
Factory setting 57 °C
Lowest value 20 °C
Highest value 64 °C
Tab. 101 Stop temperature T8 ekonomy mode
Factory setting 56 °C
Lowest value 20 °C
Highest value 57 °C
Tab. 102 Start temperature T3 comfor mode
Factory setting 64 °C
Lowest value 20 °C
Highest value 64 °C
Tab. 103 Stop temperature T8 comfort mode
Factory setting No
Alternativ No/Yes
Tab. 104 Hot water production HP 2
Factory setting No
Alternativ No/Yes
Tab. 105 Block heating
Factory setting 10K
Lowest value 0K
Highest value 30K
Tab. 106 Temperature difference circuit 1
Factory setting No
Alternative No/Yes
Tab. 107 Hot water circulation pump active