Factory settings
6 720 645 504 (2011/04) en
98
Circuit 2,
3...
Mixing valve mode Off 1
Type of heating system
Underfloor 1
Highest permitted flow temperature T1
45.0 °C 1
Lowest permitted flow temperature T1
10.0 °C 1
Heat curve
0
Room sensor
Room temperature influence (if
installed)
Acknowledge room sensor
3.0
(Auto)
0, 1
0, 1
Room temperature program
Same as Circuit 1 Heating minus Copy
to all heating circuits
0, 1
Regulator settings
P constant
I constant
D constant
Minimum PID signal
Maximum PID signal
Mixing valve running time
Mixing valve fully closed
Mixing valve start closing
Connected to output type
1.0
300.0
0.0
0 %
100 %
300s
2.0K
2.0K
Op/Cl
1
1
1
1
1
1
1
1
1
Air handling unit in circuit
No 1
Room temperature
Factory set-
ting
Access
level
Tab. 189 Factory settings, room temperature
Hot water
Factory set-
ting
Access
level
Extra hot water Extra hot water duration
Extra hot water stop temperature
0h
65 °C
0
0
Hot water peak Day of the week
Interval in weeks
Start time
Stop temperature
Maximum time
Time for warm-keeping
Wednesday
1
3:00
65,0 °C
3,0h
1,0h
0
0
0
1
1
1
Hot water program Active program
View/edit active program
Always hot
water
0
0
Hot water mode Economy 0
Hot water settings heat pump 1 / 2 Hot water production
Start temperature T3 economy mode
Stop temperature T8 economy mode
Start temperature T3 comfort mode
Stop temperature T8 comfort mode
Yes/No
47 °C/37 °C
57 °C/47 °C
56 °C/46 °C
64 °C/54 °C
1
1
1
1
1
Block heating during hot water demand No 0
Maximum temperature difference circuit 1 10K 1
Hot water circulation Hot water circulation pump active
Time settings
No 1
1
Protective anode installed No 1
Acknowledge hot water sensor E41.T3 (Auto) 1
Acknowledge hot water sensor E42.T3 (Auto) 1
Tab. 190 Factory settings hot water