Factory settings
6 720 645 504 (2011/04) en
99
External control
Factory
setting
Access
level
Heat pump x External input 1, 2 Invert input No 1
Block compressor No 0
Block additional heat No 0
Block heating at tripped underfloor tem-
perature limiter
No 1
Block heating No 0
Room temperature No
(0,0 °C)
0
Block hot water production No 0
Start collector circuit pump No 1
Alarm at low pressure in collector circuit No 1
Alarm groundwater circuit No 1
External input circuit 2, 3... Invert input No 1
Block heating at tripped underfloor tem-
perature limiter
No 1
Block heating No 0
Room temperature No
(0,0 °C)
0
Tab. 191 Factory settings External control
Installer
Factory
setting
Access
level
General Anti-seizure mode Day of the week
Start time
Minimum outdoor temperature
Wednesday
12:00
2,0 °C
1
1
1
Highest permitted flow tempera-
ture T1
45 °C
(Under-
floor)
1
Operating mode 1
Groundwater Groundwater
Compressor start delay ground-
water
No
15s
1
1
Display light switch off delay 5min 1
Time for reset of access level 20min 1
Heat pump capacity (Start-up) 1
Outputs Manual operation time 0min 1
Circulation pumps Operation alternative heating cir-
cuit pump G1
Continuous 1
Operation alternative heat car-
rier pump G2
Automatic 1
Operation alternative collector
circuit pump G3
Automatic 1
Tab. 192 Factory settings Installer