6
Page Created: 03-23-2011
Revised: 03-11-2013
WAREFORCE UH/UL 30 Technical Manual (07610-003-67-21)
Operating Parameters
Model Designation: WAREFORCE™ UH 30 WAREFORCE™ UL 30
Operating Capacity:
Racks per Hour 24 24
Dishes per Hour 600 600
Glasses per Hour 864 864
Tank Capacity (gallons):
Wash Tank 1.1 1.2
Rinse Tank 1.1 3.0
Electrical Loads (as applicable):
Wash Motor HP 0.75 0.75
Rinse Heater KW 8.2 N/A
NOTE: Always refer to the machine data plate for specific electrical and water requirements. The
material provided on this page is for reference only and is subject to change without notice.
HOT WATER SANITIZING
Water Temperatures (Fahrenheit):
Minimum Wash Temperature 150 N/A
Minimum Rinse Temperature 180 N/A
Incoming Water Temperature 110 N/A
CHEMICAL SANITIZING
Water Temperatures (Fahrenheit):
Minimum Wash Temperature N/A 120
Minimum Rinse Temperature N/A 120
Incoming Water Temperature N/A 120
Other Water Requirements:
Water Flow Pressure (PSIG) 20 20
Flow Rate Minimum (GPM) 0.44 0.48
Water Line Size (NPT) 1/2” 1/2”
Drain Line Size (NPT) 1-3/8” 1-3/8”
MIN. CHLORINE REQUIRED (PPM) N/A 50