4-75
4
OPERATION AND ADJUSTMENTS
ARBUS 400
Assembling the PH kit
When spraying is complete, clean the
main tank internally.
Spray the water remaining from the main
washing tank on the crops.
Once the water is sprayed, drain the main
tank. To do so, just pull the draining
valve string (A) located next to the tank
opening. Wind the string on the support
through the grooves so the valve stays
open until the main tank is empty.
Once the water has been thoroughly
drained, unwind the string to close the
valve again.
Draining the tank
ATTENTION!
Do not drain the machine main tank where the environment can be contaminated
and people/animals intoxicated. It is essential that the spraying circuit is properly
clean and free of residues from the previous application every time the chemical or
the equipment use is changed.
OBSERVATION:
Water remaining from the main
tank internal cleaning must be
sprayed on the crops. It must not
be discharged in areas where
the environment, animals or p
A