8
5.2 Primary Filtration Program
• Follow the steps below to access the program. Included within the Primary Filtration Menu, is the
Change Filter feature.
• Two methods for setting the lter cycle start time are possible:
1. Turn power on to the hot tub two minutes prior to the desired lter cycle start time, or
2. Press and hold the WARMER, COOLER and JETS Pump 1 buttons at the same time, to
reset the control panel and start the power-up sequence.
A. Cleanup “Blow-Out” Cycle
This cycle is activated once every 24 hours in either Standard or Economy mode. The Cleanup
Cycle shall start before the rst ltrations cycle. Pump 1 will activate for 1 minute and then shut off.
Then Pump 2 will activate for 1 minute and then shut off.
B. For Models J335 to J385
Two minutes after power is applied to the spa, an automatic primary ltration cycles begins. The
circulation pump is activated and set to run for 8 hours a day (factory default). The circulation pump
draws water through the skimmer bag and one of two lter cartridges to effectively remove small
debris in your spa. During the primary ltration cycle, the circulation pump and CLEARRAY are acti-
vated. The factory default setting is PF2. This setting is programmable.
Note: The circulation pump also supplies heated water to the spa when the heater turns on. Any
time the circulation pump runs outside of a programmed cycle (except for PF0 and PF6), that
run time will reduce the length of the next cycle.
C. For Models J315 and J325
Your new spa includes a 24-hour primary ltration system, which lters the water continuously
(factory default). The circulation pump draws water through the skimmer bag and one of the two lter
cartridges to effectively remove small debris in your spa. The factory default setting is PF6. This set-
Menu button Action Result
Press once
To access the Primary Filtration Menu. The LED will display “PF.”
or
Press once
Activates the system for changes. Last programmed cycle blinks once on
the display.
or
Press
continually
Scrolls through the menus as follows: , , , , ,
, , or
Press once
The new programmed cycle will blink twice on the display to conrm your
selection.
No ltration
4 hours of ltration per day
8 hours of ltration per day (default setting for J-335 to J-385)
12 hours of ltration per day
16 hours of ltration per day
20 hours of ltration per day
24 hours of ltration per day (default setting for J-315 and J-325)
2 hours of ltration – 4 times per day
3 hours of ltration – 4 times per day