EasyManua.ls Logo

Jacuzzi LED Series - Watchdog Error (- - -); Testing Flow;Pressure Switch

Jacuzzi LED Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
8.1E No Heat or Not Enough Heat (All Models)
Symptoms: Circulation pump (heating pump) is turning, panel heat indicator not lit,
panel is NOT ashing FL1.
Standard Troubleshooting Approach
Put hot tub in primary
ltration mode (pg. 8).
Set temperature high
enough to initiated a heat
call. Remove power to hot
tub then plug in a spare
control panel. Turn power
on. Does indicator work
now?
Replace control panel.
Verify that ow switch
padde is not bouncing and
address possible restriction
problems.
Jump out ow switch pins at
board. Does heat indicator
come on?
Replace circuit board.
No
No
Yes
Yes

Table of Contents

Other manuals for Jacuzzi LED Series

Related product manuals