UMG 96RM
Error messages
The UMG 96RM shows three different error messages
on the display:
- warnings,
- serious error and
- metering range exceedances.
If there are warnings and serious errors, the error
message is indicated by the symbol "EEE" followed by
an error number.
Symbol for an error
message
Error number
The three-digit error number is composed of the error
description and (if detectable by the UMG 96RM)
one or more error causes.
Symbol for an error
message
Description of the error
Error cause
Example of error message 911:
The error number is composed of serious error 910
and internal error cause 0x01.
In this example, an er-
ror occurred when read-
ing the calibration from
the EEPROM. The device
must be sent to the manu-
facturer for inspection.