78
UMG 96RM
Technical data
General
Net weight 290 g
Device dimensions approx. l = 42 mm, b = 97 mm, h = 100 mm
Service life of the backlight 40,000 hours (50% of initial brightness)
Transport and storage
The following information applies for devices that are transported or stored in their original packaging.
Free fall 1 m
Temperature K55 (-25 °C to +70 °C)
Relative humidity 0 to 90% RH
Ambient conditions during operation
The UMG 96RM is intended for use in weather-protected, fixed locations.
Protection class II according to IEC 60563 (VDE 0106, part 1).
Rated temperature range K55 (-10 °C .. +55 °C)
Relative humidity 0 to 75 % RH
Operational altitude 0 .. 2000 m above sea level
Degree of pollution 2
Installation position any
Ventilation Forced ventilation is not required.
Foreign body and water protection
- Front
- Front with seal (optional)
- Back
IP40 according to EN60529
IP54 according to EN60529
IP20 according to EN60529