7
Changing the printed circuit board A
To remove:
1. Remove the face plate, top cover, belt cover and
front cover. (Refer to page 1 to 4)
2. Remove the setscrews A (2 pcs.) and remove the belt
cord guide.
3. Remove the setscrews B (4 pcs.) and disconnect all
the connectors from the printed circuit board A.
Remove the printed circuit board A.
To attach:
1. Follow the steps of removal procedure in reverse.
* Refer to page 11 for how to connect/ disconnect
the connectors to the printed circuit board A.
Setscrew BSetscrew B
Setscrew B
Setscrew A
Belt cord guide
Setscrew A
Setscrew B
Printed circuit board A