6.3 Cable Selection
Please select cable according to the following table.
Table 6-3 Specification of Cables for Electrical Connection
Inverter
Cable range( AWG)
Cable recommended
( AWG)
DC side
AC side
DC side
AC side
PV+、 PV-
U、 V、 W
PE
PV+、 PV-
U、 V、 W
PE
JNP2K2L-V5
14-12
14-12
12
12
12
12
JNP3KL-V5
12-10
12-10
12
10
10
12
JNP3K7L-V5
12-10
12-10
12
10
10
12
JNP4KL-V5
12-10
12-10
12
10
10
12
6.4 AC Side Electrical Connection
Notice
!
It’s forbidden to connect several inverters in parallel to one set of pump!
Danger!
Ensure that all cables have no charge before electrical operation!