39
Caution
JN2K2L-V5, JN3KL-V5, JN3K7L-V5, JN4KL-V5,AC input is single phase 220-240V,
50/60Hz.
AC input voltage frequency is 50Hz/60Hz
6.5 DC Side Connection
Danger
When carrying out connection between PV array and inverter, the PV array
should be covered with opaque materials and the DC-SWITCH should be
disconnected, otherwise, the PV array may generate dangerous voltage, cause
casualty. The Non-professionals do not make the connection operation.
Warning
Before connecting PV array to the inverter, ensure the earth impedance between PV array
and ground is not less than 1Mohm.
Note
If there is more strings PV modules in parallel, each string PV module
should be with the same model, the same number of PV modules, the same
inclination angle, the same azimuth angle, and the same cross-sectional
area of the connecting wires.
Inspect every system carefully before installation.