82
value of
Imotor.
Fault106
Array
over-voltage
Inverter
shutdown and
will restart
automatically
after
malfunction
disappears.
DC input
voltage
higher than
maximum
input voltage
of inverter.
Please check
maximum
output voltage
of array and
make sure this
voltage is
below inverter
maximum input
voltage.
Fault107
Array
over-current
Inverter
shutdown and
will restart
automatically
after the fault
disappears.
Input current
of inverter
higher than
rated
maximum
value.
If this happen,
please contact
SUPPLIER.
Fault108
Inverter AC output
over current
Inverter
shutdown and
will restart
automatically
after the fault
disappears.
1. Power
capacity of
pump motor
is higher
than rated
output.
2. Pump
motor
locked-rotor
, or
1. Please
inspect
whether pump
motor is
normal.
2. Please
inspect
whether
pipeline
system is in

Table of Contents