Table 6: Coil only capacity
Outdoor unit model Indoor coil model Indoor coil
width (in.)
CFM range Rated CFM Net cool
(MBH)
Sens cool
(MBH)
SEER2 EER2
RAC13442B21S XAFD42E 24.5 1200—1600 1400 41.00 32.20 13.50 11.50
RAC13442B21S XAFD48F 24.5 1200—1600 1400 41.00 31.80 13.50 11.50
RAC13442B21S XAHC48F 21.0 1200—1600 1400 41.00 31.80 13.50 11.50
RAC13442B21S XAHD42E 24.5 1200—1600 1275 40.50 30.80 13.50 11.50
RAC13442B21S XAHD48F 24.5 1200—1600 1400 41.00 31.80 13.50 11.50
RAC13442B21S XAUC42E 21.0 1200—1600 1400 40.00 31.40 13.40 11.25
RAC13442B21S XAUC48F 21.0 1200—1600 1400 41.00 31.80 13.50 11.50
RAC13448B21S XAFC48F 21.0 1400—1800 1525 47.00 34.20 13.40 11.00
RAC13448B21S XAFC60G 21.0 1400—1800 1525 47.50 34.60 13.40 11.00
RAC13448B21S XAFD48F 24.5 1400—1800 1525 47.00 34.40 13.40 11.00
RAC13448B21S XAFD60G 24.5 1400—1800 1525 47.50 34.60 13.40 11.00
RAC13448B21S XAHC48F 21.0 1400—1800 1525 47.00 34.40 13.40 11.00
RAC13448B21S XAHC60G 21.0 1400—1800 1525 47.50 34.60 13.40 11.00
RAC13448B21S XAHD48F 24.5 1400—1800 1525 47.00 34.40 13.40 11.00
RAC13448B21S XAHD60G 21.0 1400—1800 1525 47.50 34.60 13.40 11.00
RAC13448B21S XAUC48F 21.0 1400—1800 1525 47.00 34.20 13.40 11.00
RAC13448B21S XAUC60G 21.0 1400—1800 1525 47.50 34.60 13.40 11.00
RAC13448B21S XAUD60G 24.5 1400—1800 1525 47.50 34.60 13.40 11.00
RAC13460B21S XAFC60G 21.0 1520—1920 1725 55.50 40.50 13.40 11.00
RAC13460B21S XAFC60H 21.0 1520—1920 1725 55.50 41.00 13.40 11.00
RAC13460B21S XAFD60G 24.5 1520—1920 1725 55.50 40.50 13.40 11.00
RAC13460B21S XAFD60H 24.5 1520—1920 1725 55.50 41.00 13.40 11.00
RAC13460B21S XAHC60G 21.0 1520—1920 1725 55.50 40.50 13.40 11.00
RAC13460B21S XAHC60H 21.0 1520—1920 1725 55.50 41.00 13.40 11.00
RAC13460B21S XAHD60G 21.0 1520—1920 1600 55.50 39.50 13.40 11.00
RAC13460B21S XAHD60H 24.5 1520—1920 1700 55.50 40.50 13.40 11.00
RAC13460B21S XAUC60G 21.0 1520—1920 1725 55.50 40.50 13.40 11.00
RAC13460B21S XAUD60G 24.5 1520—1920 1725 55.50 40.50 13.40 11.00
RAC13460B21S XAUD60H 24.5 1520—1920 1725 55.50 41.00 13.40 11.00
Coil only capacity data notes
For rated condition information, see Air handler capacity data notes.
SEER2: requires a blower time delay unless a standard furnace is equipped with one.
A cell with no value means not applicable.
PSC furnaces use coil only ratings.
Furnace capacity - 1.5 ton
Table 7: Furnace capacity - 1.5 ton
Outdoor unit model Furnace model Furnace width
(in.)
Indoor coil
model
Rated CFM Net cool
(MBH)
Sens cool
(MBH)
SEER2 EER2
RAC13418B21S RGF19026AE08MP13 17.5 XAFB24B 550 18.00 12.80 14.25 12.00
RAC13418B21S RGF19026AE08MP13 17.5 XAHB24B 550 18.00 12.80 14.25 12.00
RAC13418B21S RGF19040AE10MP13 14.5 XAFA18A 525 17.60 12.20 13.75 11.75
RAC13418B21S RGF19040AE10MP13 14.5 XAFA24B 475 17.70 12.00 14.25 12.00
RAC13418B21S RGF19040AE10MP13 14.5 XAHA18A 525 17.60 12.20 13.75 11.75
RAC13418B21S RGF19040AE10MP13 17.5 XAHB24B 550 18.00 12.70 14.25 12.00
RAC13418B21S RGF19060AE10MP13 14.5 XAFA18A 525 17.70 12.30 14.00 12.00
RAC13418B21S RGF19060AE10MP13 14.5 XAFA24B 675 18.00 13.60 14.25 12.00
RAC13418B21S RGF19060AE10MP13 14.5 XAHA18A 675 18.00 13.60 14.00 11.75
RAC13418B21S RGF19060AE10MP13 17.5 XAHB24B 525 18.00 12.50 14.25 12.00
RAC13418B21S RGF19060AE10MP13 14.5 XAUA18A 525 17.70 12.30 14.00 12.00
RAC13418B21S RGF19060AE10MP13 14.5 XAUA24B 675 18.00 13.60 14.25 12.00
RAC13418B21S RGF19060BE12MP13 17.5 XAFB24B 550 18.00 12.70 14.25 12.00
RAC13418B21S RGF19080BE12MP13 17.5 XAFB18A 600 18.00 13.00 14.25 12.00
RAC13418B21S RGF19080BE12MP13 17.5 XAFB24B 600 18.00 13.10 14.50 12.25
Technical Guide: RAC Series RAC134 Models - 13.4 SEER2 Split-System Air Conditioner - Single-Phase16