Table 41: Cooling performance data - 5 ton - indoor coil: XAFC60GXXN1
IDCFM 1525 1725 1925
ID DB
(°F)
80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
Air
temperature
entering
outdoor unit
(°F)
ID WB
(°F)
57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
T.C. 48.9 51.9 52.0 56.4 61.2 50.8 53.1 53.1 57.6 61.9 52.8 54.3 54.3 58.7 62.6
S.C. 48.2 45.6 38.6 38.6 31.5 50.2 48.5 40.9 40.9 33.0 52.1 51.4 43.2 43.3 34.5
85
kW 4.48 4.51 4.50 4.52 4.53 4.57 4.60 4.60 4.62 4.64 4.67 4.70 4.70 4.71 4.74
T.C. 47.7 50.2 49.7 54.4 59.8 49.6 51.4 50.7 55.5 60.6 51.6 52.5 51.7 56.6 61.4
S.C. 47.1 45.2 37.7 37.9 31.8 49.0 48.0 39.9 40.3 33.4 50.9 50.8 42.0 42.7 34.9
95
kW 4.90 4.93 4.92 4.95 4.95 5.00 5.03 5.02 5.05 5.06 5.10 5.13 5.12 5.14 5.17
T.C. 45.5 47.6 47.3 52.0 56.8 47.2 48.6 48.2 52.9 57.5 48.9 49.6 49.0 53.7 58.3
S.C. 44.9 43.8 36.6 37.0 30.5 46.6 46.1 38.8 39.3 31.9 48.3 48.5 40.9 41.6 33.4
105
kW 5.45 5.47 5.48 5.49 5.51 5.54 5.57 5.57 5.59 5.61 5.64 5.66 5.67 5.69 5.71
T.C. 43.3 45.0 45.0 49.7 53.9 44.8 45.8 45.6 50.2 54.5 46.3 46.7 46.2 50.8 55.2
S.C. 42.7 42.5 35.6 36.2 29.1 44.2 44.3 37.7 38.4 30.5 45.7 46.1 39.8 40.5 31.9
115
kW 6.00 6.01 6.04 6.03 6.06 6.09 6.10 6.13 6.13 6.16 6.18 6.19 6.22 6.24 6.26
Cooling performance data notes
All capacities include indoor fan heat. kW values are for the system (outdoor + indoor).
Multipliers for determining the performance with other
indoor sections
Note: For dry bulb temperatures different than those listed (between 73°F to 87°F), sensible
capacity increases by 1060 Btu/h per 1000 CFM per degree above the listed temperature and
decreases by 1060 Btu/h per 1000 CFM per degree below the listed temperature.
Cool multiplier air handler - 5 ton
Table 42: Cool multiplier air handler - 5 ton
Air handler model Indoor coil model Total capacity Sensible capacity kW
XAFC60G 1.00 1.00 1.00
XAFC60H 1.00 1.01 1.00
XAFD60G 1.00 1.00 1.00
XAFD60H 1.00 1.01 1.00
XAHC60G 1.00 1.00 1.00
XAHC60H 1.00 1.01 1.00
XAHD60G 1.00 0.98 1.00
XAHD60H 1.00 1.00 1.00
XAUC60G 1.00 1.00 1.00
XAUD60G 1.00 1.00 1.00
XAUD60H 1.00 1.01 1.00
JHVTC60HBCC2N1 0.99 0.95 0.93
JHVTD60HBCC2N1 1.00 0.96 0.94
JMET16CS2N1 XAFC60G 1.00 0.96 0.96
JMET16CS2N1 XAFC60H 1.00 0.98 0.94
JMET16CS2N1 XAHC60G 1.00 0.96 0.96
JMET16CS2N1 XAHC60H 1.00 0.98 0.94
JMET16CS2N1 XAUC60G 1.00 0.96 0.96
JMET18DS2N1 XAFD60G 1.00 0.96 0.94
JMET18DS2N1 XAFD60H 1.00 0.96 0.94