Settings & Registrations
5-15
5.5.6 Setting the inactivity timeout timer
If a call event is left without operation for a while, the call event is automatically ended after the
setting time is elapsed. The inactivity timeout timer can be set as follows.
■ Procedure ■
1
1
1
.
.
.
Move the cursor to 7. Inactivity timeout,
and press ENT.
The screen as shown at right is displayed.
Change the settings as appropriate.
1. ACKed distress alert
The acknowledged distress alert events
sent from the own ship:
- The range is 00 (OFF) to 60 minutes.
2. RCVed other distress
The distress events of other ships
- The range is 00 (OFF) to 60 minutes.
3. Non-distress call
Routine, safety and urgency events
- The range is 00 (OFF) to 60 minutes.
4. Other communications
Communications without using DSC
- The range is 010 to 600 seconds.
5.5.7 Registering the DSC call list
To call the station using the DSC, registers the station names, MMSI and the calling frequencies
as follows.
■ Procedure ■
1
1
1
.
.
.
Move the cursor to 8. DSC call list, and
press ENT.
The screen as shown at right is displayed.
2
2
2
.
.
.
Move the cursor to the line to be
changed and press ENT to display the
frequency list as shown at right.
3
3
3
.
.
.
Input data as appropriate using the
numeric keypad or jog dial.
Upto 20 channels for every 20 stations can
be registered.
When finished, press CANCEL key.
7.5.7)Inactivity timeout
1.ACKed distress alert:OFF
2.RCVed other distress:OFF
3.Non-distress call :15min
4.Other communications:030sec
0.Back
7.5.8)DSC call list
No Station name MMSI
01
02
03
04
05
06
07
08
JRC Mitaka1
431000001
7.5.8)DSC call list(FRQ)
Name:JRC Mitaka1
MMSI:431000001
No Rx[kHz] Tx[kHz] Category
01
02
03
04
05
06
2177.00
4219.50
4220.00
4220.50
2189.50
4208.00
4208.50
4209.00
RTN
RTN
RTN
RTN