Maintenance & Inspection
6-10
6.3.4 BAM alert table
The BAM alerts detected by this equipment are as follows.
Alert
ID
Alert title Alert description
Priority
Cate
gory
Alert
instance
Responsi
bility
transfer
Occurrence conditions
Recovery conditions
3008 TX POWER: FAIL
PA Hi-temp
No Transmission
RX works OK.
Warning
B 1 ✓
Detected high temperature of
the PA heat sink.
Returned to normal
temperature of the PA heat
sink.
3013 POSITION 4H OLD
Position is too old.
Input new position.
Caution
B
1
Four hours passed without
position data input.
Input new position data.
3015 ANTENNA: TUNER
ATU Hi-temp
No Transmission
RX works OK.
Warning
B
1 ✓
Detected high temperature in
the antenna tuner.
Returned to normal
temperature in the antenna
tuner.
3016 SARPOSITION LOST
No position data.
Input data manually.
Caution
B
1
No position data input in 1
minute after startup, or the
position data is interrupted for
10 minutes.
Input new position data.
3079 PRINTER: ERROR
Check printer
condition.
Caution
B
n
*7
Detected serial printer error.
Recovered the serial printer
error.
3122
DISTRESS: RX
DIST-ID:xxxxxxxxx
*1
ccc…
*2
Warning
B nn
*8
✓
Received distress call.
Terminated the event of the
receiving distress call.
DISTRESS: RELAY
DIST-ID:xxxxxxxxx
*1
RLY-ID:yyyyyyyyy
*3
Warning
B
nn
*8
✓
Received distress relay call.
Terminated the event of the
receiving distress relay call.
URGENCY: RX
RxID:xxxxxxxxx
*4
Individual call
*5
Warning
B
nn
*8
✓
Received urgency call.
Terminated the event of the
receiving urgency call.
3123
SAFETY: COM
RxID:xxxxxxxxx
*4
Individual call
*5
Caution
B
nn
*8
Received safety call (Individual
or Area).
Terminated the event of the
receiving safety call.
SAFETY: POS
RxID:xxxxxxxxx
*4
Individual call
Caution
B
nn
*8
Received safety call (Position
request).
Terminated the event of the
receiving safety call.
SAFETY: TEST
RxID:xxxxxxxxx
*4
Individual call
Caution
B
nn
*8
Received safety call (Test).
Terminated the event of the
receiving safety call.
ROUTINE: COM
RxID:xxxxxxxxx
*4
Individual call
*6
Caution
B
nn
*8
Received routine call
(Individual or Group).
Terminated the event of the
receiving routine call.
ROUTINE: POLL
RxID:xxxxxxxxx
*4
Individual call
*6
Caution
B
nn
*8
Received polling call
(Individual or Group).
Terminated the event of the
receiving polling call.
*1: ID number (MMSI) of the ship that sent the distress call is displayed.
*2: Nature of distress (Fire, Man overboard, etc.) is displayed.
*3: ID number (MMSI) of the ship that sent the distress relay call is displayed.
*4: ID number (MMSI) of the received calling station is displayed.
*5: "Individual call" or "Area call" is displayed.
*6: "Individual call" or Group ID number is displayed.
*7: 1 or 2
*8: From 1 to 99