Maintenance & Inspection
6-2
6.2 Self diagnosis inspection
The following describes the procedure for performing self diagnosis in the 6.1 Self diagnosis
menu.
Procedure
1
1
1
.
.
.
Press FUNC 8
TEST
.
The 6.1 Self diagnosis menu is displayed.
2
2
2
.
.
.
Select Transceiver, Controller/DTE, or
DSC/NBDP loop.
When Transceiver is selected, the screen
at right is displayed.
For DSC/NBDP loop, a shortcut menu for
diagnosing the modem is as shown in the
screen at right.
3
3
3
.
.
.
In the above screen, press ENT, select
the diagnosis mode with the jog dial, and
press ENT. Self diagnosis is performed.
The following test modes are available:
6.1.1) Transceiver ... ALL (all modes)
TRX&MODEM
PA&ATU
WKR MODEM
TRX
PA
ATU
6.1.2) Controller ...... ALL (all modes)
DGT CKT
AF output
LCD&LED
Speaker
Printer
DTE
- If the jog dial is turned while the cursor is at Target when Transceiver is
selected, the diagnosis items of each unit and previous diagnosis results can
be browsed.
- To cancel self diagnosis midway, press the CANCEL key.
- The results of the self diagnosis are stored as a log, and up to 10 logs can be
confirmed from the 6.1.3 Transceiver log or 6.1.4 Controller/DTE log menu.
- The self diagnosis results are printed out to the connected printer. Additionally,
the state can be set with the menu 6. Printout as follows;
Valid: Target & result of every item, Simple: Target & the result, and Invalid
- The self diagnosis test contents and results are as shown below.
Note
6.1.1)Transceiver
Target :ALL
- ATU -
1.Serial I/F :
2.Band1-Input :
3.Band1-Tune :
4.Band2-Input :
5.Band2-Tune :
6.Band3-Input :
7.Band3-Tune :
6.1.1)Transceiver
Target :TRX&MODEM
- ATU -
1.Serial I/F :
2.Band1-Input :
3.Band1-Tune :
4.Band2-Input :
5.Band2-Tune :
6.Band3-Input :
7.Band3-Tune :
6.1.1)Transceiver
Target :ATU
- ATU -
1.Serial I/F :OK
2.Band1-Input :Checking
3.Band1-Tune :
4.Band2-Input :
5.Band2-Tune :
6.Band3-Input :
7.Band3-Tune :
6.1)Self diagnosis
1.Transceiver
2.Controller/DTE
3.Transceiver log
4.Controller/DTE log
5.DSC/NBDP loop
6.Printout :Valid
0.Back