Maintenance & Inspection
6-14
050 Controller MODEM lost
Detected a serial communication
error with the WKR MODEM.
Please contact JRC or
our agency.
051 Controller CTRL1 lost
Detected a serial communication
error with the No.1 controller.
Please contact JRC or
our agency.
052 Controller CTRL2 lost
Detected a serial communication
error with the No.2 controller.
Please contact JRC or
our agency.
095 Controller CTRL1 memory
Detected a memory error on the
No.1 controller.
Please contact JRC or
our agency.
096 Controller CTRL2 memory
Detected a memory error on the
No.2 controller.
Please contact JRC or
our agency.
059
Data
terminal
My/OTH DTE lost
Detected a serial communication
error between controller (ID:1)
and DTE.
Note) My or OTH indicates the
relationship between that data
terminal and the controller
displaying this information.
Check the data
terminal cable
connection, or the
condition of the data
terminal.
060
Data
terminal
My/OTH DTE lost
Detected a serial communication
error between controller (ID:2)
and DTE.
Note) My or OTH indicates the
relationship between that data
terminal and the controller
displaying this information.
Check the data
terminal cable
connection, or the
condition of the data
terminal.
062
Data
terminal
My/OTH DTE
USB-IC
Detected the SPI communication
error at the USB circuit of the
data terminal connected to the
controller (ID:1).
Note) My or OTH indicates the
relationship between that data
terminal and the controller
displaying this information.
Please contact JRC or
our agency.
063
Data
terminal
My/OTH DTE
USB-IC
Detected the SPI communication
error at the USB circuit of the
data terminal connected to the
controller (ID:2).
Note) My or OTH indicates the
relationship between that data
terminal and the controller
displaying this information.
Please contact JRC or
our agency.
(2) JSS-2250/2500
(*) 500W model only
MI
Number
Source
Unit
Display Contents
Troubleshooting
Procedure
001 PA Overcurrent (A)
Detected an overcurrent (6.8A at
AC, or 5.1A at DC) in the PA(A).
Re-tune or operate on
another frequency.
002 PA Overload (A)
Detected the condition SWR > 3 in
the PA(A).
Re-tune or operate on
another frequency.
003 PA Overcurrent (B) *
Detected an overcurrent (6.8A at
AC, or 5.1A at DC) in the PA(B).
Re-tune or operate on
another frequency.
004 PA Overload (B) *
Detected the condition SWR > 3 in
the PA(B).
Re-tune or operate on
another frequency.
007 PA SWR/Overload
Detected the condition SWR > 3 or
overload at the PA output.
Re-tune or operate on
another frequency.
008 PA
High-temp
On TX, detected high temp (99°C or
more) at the radiator in the PA unit.
Stop transmission, or
reduce output.
010 PA RBK overcurrent Detected RBK overcurrent.
Please contact JRC or
our agency.
011 PA High-VDD (A)
Detected overvoltage (132V or more)
at the drain of the FET in the PA(A).
Please contact JRC or
our agency.
012 PA Low-VDD (A)
Detected low voltage (80V or less)
at the drain of the PA(A) FET.
Please contact JRC or
our agency.
013 PA High-VDD (B) *
Detected overvoltage (132V or more)
at the drain of the FET in the PA(B).
Please contact JRC or
our agency.
014 PA Low-VDD (B) *
Detected low voltage (80V or less)
at the drain of the PA(B) FET.
Please contact JRC or
our agency.