33
6-3. Sewing through the use of the counter
B D C
A
Counter screen
A
is displayed to accept setting.
The value for the counter can only be set under
the input mode. In the case of the sewing mode,
press READY key
o enter the input
mode.
2) Selection of kinds of counters.
Press ITEM SELECT key
to display the
pictograph
B
which indicates the counter type in
reverse video.
Press DATA CHANGE key
, and select
the counter you desire from among the kinds of
counters below.
3) Change of counter set value.
Press ITEM SELECT key
to display the set value
C
of the counter in reverse video.
Press DATA CHANGE key
and input the set value until count-up is reached.
4) Change of existing counter value.
Press ITEM SELECT key
to display the current value
D
of the counter in reverse video.
Press RESET key
and the value on the way of counting can be cleared.
In addition, it is possible to edit the numerical value with DATA CHANGE key
.
(1) Setting procedure of the counter value
1) Call counter setting screen.
Press MODE key
, in the state where
SET READY LED
goes out, to display the
mode screen.
Place "02 Counter setting" in the selected state
with ITEM SELECT key
. Press EDIT key
EDIT key
to display the counter screen
A
.