– 68 –
(2) Setting items for the polygonal-shape stitching steps
Data No. Item name
Unit of
change
Input range
Step 01
S201 Step changeover ―
: Number of stitches
: One-touch switch
: Multi-layered part
S203 Sensor value to change over the
step
1
1000 to 3000
S204 Number of stitches
(seam length in mm)
1 stitch
1 to 10000
S205 Stitch length
(the number of stitches per inch,
the number of stitches per 3 cm)
0.1 mm
-5.0 to 5.0
S206 Reverse feed stitch length 0.1 mm
-5.0 to 5.0
S207 Needle thread tension, left 1
0 to 200
S208 Needle thread tension, right 1
0 to 200
S210 Stitch length 2 0.1 mm
-5.0 to 5.0
S211 Needle bar stop position at the
time of pause
―
:
Stop with the needle up
:
Stop with the needle down
Data
No.
Item name
Unit of
change
Input range
S097 Multi-layered portion
changeover, number
of stitches to be
sewn before turning
OFF the changeover
function
1 stitch
0 to 200 ― ―
0 to 200
S100 Tension correction
speed chart
―