No. Function Abbreviation Command Output Setting Input Setting Parameter
1
Setting Parameter
2
Setting range Remarks
code setting range setting range range
13 12 Up US stop command Valid oH. 1 to 17 Invalid Invalid Delay time (d.) 0 : Without delay UP position stop command (speed designated with other command
oL. 1 to 17 1 to 999 X 1mS is neglected.)
—— Command is executed without delay time with delay time “0”. For
others, UP position stop command is valid within set delay time
and command is invalid after lapse of delay time.
14 13 HS Needle up/down Valid oH. 1 to 17 Invalid Invalid Delay time (d). 0 : Without delay When command is executed, sewing machine rotates normally,
command oL. 1 to 17 1 to 999 X 1 mS and needle goes to UP position when it is in DOWN position and
vice versa. Even if there is speed limitation with other command, it
—— is neglected.
Command is executed without delay time with delay time “0”. For
others, command is valid within set delay time and command is
invalid after lapse of delay time.
15 14 rSW Rsw command Valid oH. 1 to 17 Invalid Invalid Delay time (d.) 0 : Without delay When reverse rotation command is executed, sewing machine
oL. 1 to 17 1 to 999 X 1 mS brakes by reverse rotation from angle set in function setting No.
—— 19 and stops. Command is executed without delay time with delay
time “0”. For others, command is valid within set delay time and
command is invalid after lapse of delay time.
16 15 AnGA Angle AND conditional Valid oH. 1 to 17 Valid iH. 1 to 53
Skip destination step No.
1 to 20 Angle (A.) 0 : Without delay Step moves to next one after lapse of set angle, and when all input
branch oL. 1 to 17 iL. 1 to 53 (Sn) 1 to 359° conditions are completed (AND input), step moves to skip
destination step No. (Angle reference is angle from UP position
miss.)
17 16 AnGo Angle OR conditional Valid oH. 1 to 17 Valid iH. 1 to 53
Skip destination step No.
1 to 20 Angle (A.) 0 : Without delay Step moves to next one after lapse of set angle, and when either
branch oL. 1 to 17 iL. 1 to 53 (Sn) 1 to 359° one of input conditions is completed (OR input), step moves to
skip destination step No. (Angle reference is angle from UP position
miss.)
18 17 SToP Stop command Valid oH. 1 to 17 Invalid Invalid Delay time (d.) 0 : Without delay Stop command is output and step moves to next one. When time
oL. 1 to 17 1 to 999 X 1 mS is set, step moves to next one after lapse of set time.
19 18 bT BTsw command Valid oH. 1 to 17 Invalid on/off information on/off Delay time (d.) 0 : Without delay On/off of reverse feed stitching switch is set.
(Reverse feed stitching oL. 1 to 17 (on/off) 1 to 999 X 1 mS Command is executed without delay time with delay time “0”. For
output) other set value, command is executed after lapse of back-tack
output “on” time during set time.
20 19 FL FLsw command Valid oH. 1 to 17 Invalid on/off information on/off Delay time (d.) 0 : Invalid On/off of presser lifting switch command is set.
(Presser lifting output) oL. 1 to 17 (on/off) 1 to 999 X 1 mS Command is executed without delay time with delay time “0”. For
other set value, presser lifting output “off” is executed after lapse
of presser lifting output “on” time during set time.
21 20 rEST Program reset Valid oH. 1 to 17 Invalid Program No. (Sn) 1 to 4 Invalid Initialization of step of designated program No. Step of designated
oL. 1 to 17 program is compulsorily returned to the first step.