– 101 –
(6) Setting procedure of optional power and setting procedure of jumper for input
changeover
Lists below are those of setting procedure of power voltage of optional connectors.
By setting respective jumper wires, +5V, +12V and +24V can be used.
* +5V has been set at the time of delivery from factory.
1. Input connector
2. Output connector
Caution when using optional power
1) Note that the power for optional is 0.6A in total when IPOP p.c.b. is not used, and that the power for
optional should not exceed 0.4A when IPOP p.c.b. is mounted.
3. Layout diagram of jumper for optional changeover of power
Connector No. Pin No. Setting voltage Function Jumper for optional power selection
+5V +12V +24V
CN51-1 1 Vcc4 Power voltage selected with W4 W4 1-2 W4 3-4 W4 5-6
4—GND
CN51-2 1 Vcc4 Power voltage selected with W4
4—GND
CN51-3 1 Vcc3 Power voltage selected with W3 W3 1-2 W3 3-4 W3 5-6
4—GND
CN51-4 1 Vcc3 Power voltage selected with W3
4—GND
Connector No. Pin No. Setting voltage Function Jumper for optional power selection
+5V +12V +24V
CN50-1 1 Vcc1 Power voltage selected with W1 W1 1-2 W1 3-4 W1 5-6
4—GND
CN50-2 1 Vcc1 Power voltage selected with W1
4—GND
CN50-3 1 Vcc2 Power voltage selected with W2 W2 1-2 W2 3-4 W2 5-6
4—GND
CN50-4 1 Vcc2 Power voltage selected with W2
4—GND