– 47 –
To upgrade the control program for the control box (SC-510), follow the procedure below. Upgrade operation for
the extension board (IPOP board) and operation panel (IP-100E) is performed in the same manner.
1) First, create the folders configured as shown below in a SmartMedia card and store each control program file
(* PRG) in them.
SmartMedia
P R O G
S C 5 1 0
MT******. PRG
I P******. PRG
MA******. PRG
MT******. PRG : Servomotor (SC-510 main body CTL board)
I P******. PRG : Operation panel (IP-100E)
MA******. PRG : IPOP (SC-510 expansion IPOP board)
2) Turn on the power while pressing the switches (▲) and (▼) on the front panel of the control box
simultaneously, and LED 3 circled with dotted line blinks. If LED3 does not blink, try the operation again.
CTL board LED3
IPOP board
(7) Software upgrade
WARNING :
•To prevent personal injury caused by abrupt start of the sewing machine, carry out the work after turning
OFF the power switch and a lapse of 5 minutes or more.
• If version upgrading (program rewriting) of the control program is intended for the control box (SC-510),
the program of the operation panel (IP-100E) should be updated, in the first place, with the latest version.
This action is important to avoid failure in rewriting.