– 58 –
1 Soft start The number of stitches to be sewn at a low speed when the U 0 to 9 64
function soft-start function is used at the start of sewing. (Stitches)
0 : Soft-start function is not operative.
2 Material end Material end sensor function (used in case of without panel). U 0/1 64
sensor function 0 :Material end detection function is not operative.
1 :After detecting material end, the specified number of
stitches (No. 4) will be sewn, and the sewing machine
will stop.
3
Thread trimming
Thread trimming function by material end sensor (used in U 0/1 64
function by case of without panel).
material end 0 :Automatic thread trimming function after detection of
sensor material end is not operative.
1 :After detecting material end, the specified number of
stitches (No. 4) will be sewn, and the sewing machine
will stop and perform automatic thread trimming.
4 Number of Number of stitches for material end sensor (used in case of U 0 to 19 64
stitches for without panel). (Stitches)
material end Number of stitches from detection of material end to stop of
sensor the sewing machine.
5 Flicker Flicker reducing function (If the hand lamp flickers). U 0 to 3 64
reducing 0 :Flicker reducing function is not operative.
function 1 :Less effective / 3 : Highly effective
6 Bobbin thread Bobbin thread counting function U 0/1 64
counting 0 :Bobbin thread counting function is not operative.
function 1 :Bobbin thread counting function is operative.
7 Unit of bobbin Unit of bobbin thread counting down U 0 to 2
thread 0 :Count/10 stitches
counting down 1 :Count/15 stitches
2 :Count/20 stitches
8 Number of Sewing speed of reverse feed stitching U 150 to 3000
rotation of (rpm)
reverse feed
stitching
9 Thread Thread trimming prohibiting function (used in case of without U 0/1 64
trimming panel).
prohibiting 0 :Thread trimming prohibiting function is not operative.
function 1 :Thread trimming is prohibited.
(Output of solenoid is prohibited. : Thread trimmer and wiper)
10 Setting of Position of needle bar is specified when the sewing machine U 0/1 64
needle bar stops.
stop position 0 :Predetermined lowest position
when the 1 :Predetermined highest position
sewing
machine stops.
11 Click sound Click sound of key switch mounted on PSC is specified. U 0/1 64
of key switch 0 :Click is not operative.
mounted on 1 :Click is operative.
PSC
12 Optional input/ Changeover of optional switch. U 65
output setting
13 Function of Function of prohibiting start of the sewing machine by bobbin U 0 to 2
prohibiting start thread counting
of the sewing 0 :When counting is out (-1 or less) Function of prohibiting
machine by start of the sewing machine is not operative.
bobbin threas 1 : When counting is out (-1 or less) Function of prohibiting
counter start of the sewing machine after thread trimming is operative.
2 :When counting is out (-1 or less), the sewing machine
stops once. Function of prohibiting start of the sewing
machine after thread trimming is operative.
14 Sewing counter Counting function of sewing (number of completion of process) U 0 to 2 68
0 :Sewing counter function is not operative.
1 :Sewing counter function is operative.
(for every thread trimming)
2: Sewing counter SW input function is operative. (IP-100)
(4) Function setting list (Start level ; U : User’s mode, S : Service mode)
No. Item Description Start level Setting range Indication of function setting
∗ Do not change the set values with asterisk (*) mark as they are functions for maintenance. If the standard set value set at the time
of delivery is changed, it is in danger of causing the machine to be broken or the performance to be deteriorated.
(Descriptions of setting in this list are the standard values at the time of delivery.)
However, contents of function setting are subject to change for improvement of function and performance without notice.
∗
Ref.
page