EasyManua.ls Logo

JUKI SC-510 Series - Error Code List

JUKI SC-510 Series
129 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 117 –
No. Description of error detected Cause of occurrence expected Items to be checked
SmartMedia cover open • The SmartMedia slot is open Close the cover of the slot
E000 Execution of data initialization When the machine head is changed.
(This is not the error.) When the initialization operation is executed
E003 Disconnection of synchronizer When position detection signal is not input Check the synchronizer connector (CN33,
connector from the sewing machine head synchronizer. CN43) for loose connection and disconnection.
E004
Synchronizer lower position sensor failure
When the synchronizer has broken.
Check whether the synchronizer cord has broken
E005
Synchronizer upper position sensor failure
since the cord is caught in the machine head.
E007 Overload of motor When the machine head is locked. Check whether the thread has been entangled
When sewing extra-heavy material beyond in the motor pulley.
the guarantee of the machine head. Check the motor output connector (4P) for loose
When the motor does not run. connection and disconnection.
Motor or driver is broken. Check whether there is any holdup when turning
the motor by hand.
E008 Machine head connector When the machine head connector is not Check the machine head connector (CN32)
failure(Resistance pack) properly read. for loose connection and disconnection.
E011 A SmartMedia card uninserted A SmartMedia card has not been inserted. Turn OFF the power.
E012 Read error Data on a SmartMedia card cannot be read. Turn OFF the power.
E013 Write error Data cannot be written into a SmartMedia Turn OFF the power.
card.
E014 Write protection The SmartMedia is write-protected. Turn OFF the power.
E015 Format error The SmartMedia is unformattable. Turn OFF the power.
E016 Beyond external media capacity Short of SmartMedia capacity Turn OFF the power.
E019 Beyond file size The file is too large. Turn OFF the power.
E032 File compatibility error The file is not compatible. Turn OFF the power.
E302 Tilt detection When tilt detection switch is inputted with Check whether machine head is tilted without
(MF : thread trimmer knife sensor) the power ON. turning OFF the power switch (operation of
(At the time of safety switch Position of thread trimmer knife is improper. sewing machine is prohibited for safety).
operation)
Check whether tilt detection switch cord is caught
in the machine.
Check whether tilt detection switch lever is
caught in the machine.
E331 Tape cutter (TC03) Defective cutter sensor Is air pressure appropriate?
Cutter sensor simultaneously
enabled
E332 Tape cutter (TC03) Defective assembly Is air pressure appropriate?
Cutter sensor simultaneously
disabled
E499 Simplified program data error Command parameter data is out of the range. Enter the simplified program again.
Disable the simplified prgram.
E704 Type error of simplified program Adifferent type is entered for the program Turn off the power.
or sewing machine data or data.
E730 Encoder failure When the motor signal is not properly Check the motor signal connector (CN30) for
E731 Motor hole sensor failure inputted. loose connection and disconnection.
Check whether the motor signal cord has broken
since the cord is caught in the machine head.
E733 Motor reverse rotation The motor rotates at the speed of more than Encoder wiring of the main shaft motor is
500rpm in a direction opposite to that of wrong.
indication. Power wiring of the main shaft motor is
wrong.
(1) Error code list
*
*
*
*
*
*
*
*
*
(Caution) Items marked with * are applicable only to IP-100E.

Table of Contents

Related product manuals