No. Description of error detected Cause of occurrence expected Items to be checked
E799 Thread trimming sequence Thread trimming sequence control is not There is a discrepancy between the mounted
time over finished within the specified time (3 seconds). machine head and the selected machine head.
The motor pulley diameter is different from the
preset motor pulley diameter (effective diameter).
The belt tension is loose.
E811 Overvoltage When voltage higher than guaranteed one Check whether the applied power voltage is
is inputted.
higher than the rated voltage + (plus) 10% or more.
When 220V has been inputted at 110V Check whether 110V/220V changeover switch is
setting improperly set.
400V is applied to the box of 220V (230V). In the aforementioned cases, POWER p.c.b
is broken.
E813 Low voltage When voltage lower than guaranteed one Check whether the voltage is lower than the
is inputted. rated voltage – (minus) 10% or less.
•When 110V has been inputted at 220V setting. Check whether 110V/220V changeover switch
•110V is applied to the box of 220V. is improperly set.
•Inner circuit is broken by the applied Check whether fuse or regenerative resistance
overvoltage is broken.
E906 Operation panel transmission Disconnection of operation panel cord Check the operation panel connector (CN38)
failure Operation panel has broken. for loose connection and disconnection.
Check whether the operation panel cord has
broken since the cord is caught in the
machine head.
E915 Communication error Cord of operation panel disconnected Make sure that the operation panel connector
(between operation panel and Operation panel damaged (CN121) is secured.
IPOP (expansion) board) IPOP board poorly connected or damaged
Make sure that there is no damage to the cord
due to being caught by the top of the operation
panel.
Make sure that the IPOP board and the con-
nector are secured.
E916 Communication error IPOP board poorly connected or damaged Make sure that the IPOP board and the
(between IPOP (expansion) board connector are secured.
and CTL (front cover) board)
E924 Motor driver failure Motor driver has broken.
E942 EEPROM error Data unwritable into EEPROM Turn off the power.
*
*