– 119 –
(2) IP-100E operation panel display
(Reference) Error is informed by means of the panel display and control box buzzer.
Three different kinds of screens of the panel display screen appear due to the difference of the procedures.
1) Error screen disappears when the operator removes
the cause.
Example) Cover of the slot of smart media is open.
Close the cover.
[Warning list (Error display in panel)]
No Contents and display of warning Corrective measure Remarks
A201 Replacement of needle warning Press to close warning screen, and perform
replacement of needle. Then clear the value in
the clear screen.
Press to clear the value, and perform replacement
of needle.
A202 Cleaning warning Press to close warning screen, and perform
cleaning. Then clear the value in the clear screen.
Press to clear the value, and perform cleaning.
A203 Replacement of oil warning Press to close warning screen, and perform
replacement of oil. Then clear the value in the clear
screen.
Press to clear the value, and perform repla-
cement of oil.
2) Press the reset switch, and remove the cause of er-
ror after erasing the error screen.
3) Remove the cause of error after turning OFF the power.
Refer to the sew-
ing management
information in the
instruction
manual for
IP100E/SC-510.
Refer to the sew-
ing management
information in the
instruction
manual for
IP100E/SC-510.
Refer to the sew-
ing management
information in the
instruction
manual for
IP100E/SC-510.