[Warning list (Error display in panel)]
No Contents and display of warning Corrective measure Remarks
A201 Replacement of needle warning • Press to close warning screen, and perform
replacement of needle. Then clear the value in
the clear screen.
• Press to clear the value, and perform replacement
of needle.
A202 Cleaning warning • Press to close warning screen, and perform
cleaning. Then clear the value in the clear screen.
• Press to clear the value, and perform cleaning.
A203 Replacement of oil warning • Press to close warning screen, and perform
replacement of oil. Then clear the value in the clear
screen.
• Press to clear the value, and perform repla-
cement of oil.
2) Press the reset switch, and remove the cause of er-
ror after erasing the error screen.
3) Remove the cause of error after turning OFF the power.
Refer to the sew-
ing management
information in the
instruction
manual for
IP100E/SC-510.
Refer to the sew-
ing management
information in the
instruction
manual for
IP100E/SC-510.
Refer to the sew-
ing management
information in the
instruction
manual for
IP100E/SC-510.