2. Output connector (CN124)
Connector No. Pin No. Function
CN124-1 1 Power voltage selected with W3
2 Optional output 9
3 Optional output 10
4 GND
CN124-2 1 Power voltage selected with W3
2 Optional output 11
3 Optional output 12
4 GND
CN124-3 1 Power voltage selected with W4
2 Optional output 13
3 Optional output 14
4 GND
CN124-4 1 Power voltage selected with W4
2 Optional output 15
3 Optional output 16
4 GND
Jumper for power
voltage setting
W3
You can select from among
+5, +12, and +24 V at W3
setting for supply voltage.
“+5 V” is selected at ship-
ment.
W4
You can select from among
+5, +12, and +24 V at W4
setting for supply voltage.
“+5 V” is selected at ship-
ment.
(Caution) Do not apply voltage exceeding the value set with W3 and W4 (jumpers for power voltage) to the
optional output terminal of output connector. When voltage exceeding the setting is applied,
there is the possibility that breakage or deterioration of circuit board occurs. So, be careful.