Loading...
– 92 –
3. Check
Make sure that the cover is mounted in parallel
with the body and there is no gap between the
body and the cover by visual check from side
and rear angle of the connector.
Wrong (1)
Insufficient cover
crimping
Wrong (2)
Latch unhooked
Push the point marked with the arrow.