E 45
0705.USA
8 Troubleshooting
This section is designed to help users to identify and rectify simple faults or the
consequences of operator errors themselves. When trying to locate faults, you should
follow the sequence of actions shown in the table.
NOTICE If the "remedies" above did not help to rectify the fault, please contact the
manufacturer's service organization, since further fault correction can only be
carried out by qualified service personnel.
Fault Possible cause Remedy
Vehicle will
not move
Battery connector not
plugged in
Check battery connector and plug in if
necessary
Battery holder not fitted
(o)
Fit battery holder
Switch latch in
position "0"
Turn switch latch to position "I"
Battery charge
too low
Check battery charge, recharge
battery if necessary
Faulty fuse Check fuses
Load cannot
be raised
Vehicle not
ready for use
Work through all the remedies listed
under "Vehicle will not move"
Hydraulic oil level too
low
Check hydraulic oil level
Load too heavy Check maximum load capacity
(see nameplate)
Battery charge monitor
has switched off and
indicates "STOP"
(CANDIS, o)
Charge battery
LED on discharge
indicator lights up yellow
(LEA, t)
Charge battery
Coast LED lights up
yellow
Charge battery
Faulty fuse Check fuse 2F1
No display on
battery
discharge
indicator
Vehicle not
ready for use
Check battery connector and plug in if
necessary
Faulty fuse Check fuse 6F1