8.6 Set ELH 2415 / 2425 / 2435 Charger Characteristics with CanCode
Parameter setting example
The following example shows the charging characteristics parameter setting for a
maintenance-free battery with 201 - 300 Ah.
Requirements
CanCode and CanDis are available.
Procedure
Press the O key (82).
Enter the master code.
Enter the four-digit parameter number "1388" and confirm with the SET key.
Enter sub-index (enter "2") and confirm with the SET key.
Z
The parameter and sub index are displayed alternately with the current reading.
E.g. (1388-2<->0000-1) corresponds to the 100 - 300 Ah PzS wet cell battery or
PzM charging characteristic.
Enter parameter "5" according to the parameter list and confirm with the SET key.
Z
The LED of the O key (82) switches briefly to steady light and start flashing again
after approx. 2 seconds.
Z
If the entry is incorrect, the LED of the O key (82) turns red. Enter the parameter
number again to repeat the setting.
Z
The parameter and sub index are displayed alternately with the current reading
(1388-2<->0000-5).
Charging characteristics for the maintenance-free battery with 201 - 300 Ah are set.
Z
Travel is disabled while the parameters are being entered.
Storing the parameter
Requirements
The parameter is now entered.
Procedure
Run "SaveParameters" by pressing 1-2-3-Set.
Press the O key.
The parameter is now saved.
Testing an altered parameter
Requirements
The parameter is now saved.
Procedure
Press the O key (82).
Enter the master code.
Enter the four-digit parameter number "1388" and confirm with the Set key.