Maintain ambient airflow for normal switch operation. If the airflow is blocked or restricted, or if the
intake air is too warm, the switch might overheat, leading to the switch temperature monitor shutting
down the device to protect the hardware components.
Table 24 on page 59 provides the required environmental conditions for normal switch operation for all
EX4650 models.
Table 24: EX4650 Environmental Tolerances
ToleranceDescription
No performance degradation to 6562 feet (2000 meters)Altitude
Normal operation ensured in relative humidity range of 5% through 90%,
noncondensing
Short-term operation ensured in relative humidity range of 5% through
93%, noncondensing
NOTE: As defined in NEBS GR-63-CORE, Issue 3, short-term events can
be up to 96 hours in duration but not more than 15 days per year.
Relative humidity
Normal operation ensured in temperature range of 32° F through 104° F
(0° C through 45° C)
Nonoperating storage temperature in shipping container: –40° F through
158° F (–40° C through 70° C)
Temperature
Designed to comply with Zone 4 earthquake requirements per NEBS
GR-63-CORE, Issue 3.
Seismic
NOTE: Install EX4650 devices only in restricted areas, such as dedicated equipment rooms and
equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical
Code, ANSI/NFPA 70.
59

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4650 Series and is the answer not in the manual?

Juniper EX4650 Series Specifications

General IconGeneral
CoolingFront-to-back or back-to-front airflow
Rack Units1U
MAC address table size288, 000 entries
Memory16 GB
Storage64 GB SSD
Power SupplyDual redundant, hot-swappable
Junos OSSupported
Jumbo frames9216 bytes
Operating temperature0°C to 40°C (32°F to 104°F)
Input voltageAC: 100-240V
FansHot-swappable, redundant
Operating humidity5% to 90% (non-condensing)
Ports48 x 10GbE SFP+/SFP28 ports 8 x 40GbE QSFP+/100GbE QSFP28 ports

Related product manuals