To mount the switch on four posts of a rack:
1. Place the switch on a flat, stable surface.
NOTE: The four-post rack-mount kit ships with the short front-mounting brackets attached to
the side mounting-rails. If you want to recess the switch in the rack, you must unscrew the short
front-mounting brackets from the side mounting-rails by using the Phillips (+) screwdriver and
attach the long front-mounting brackets to the side mounting-rails.
2. Align the side mounting-rails along the side panels of the switch chassis. Align the two holes in the rear
of the side mounting-rails with the two holes on the rear of the side panels.
3. Insert 4x6-mm Phillips flat-head mounting screws into the two aligned holes and tighten the screws
by using the screwdriver. Ensure that the remaining four holes in the side mounting-rails are aligned
with the four holes in the side panel. See Figure 32 on page 85.
Figure 32: Attaching the Side Mounting-Rail to the Switch Chassis
g022533
4. Insert the 4x6-mm Phillips flat-head mounting screws into the remaining four holes in the side
mounting-rails and tighten the screws by using the screwdriver.
5. Have one person grasp both sides of the switch, lift the switch, and position it in the rack, aligning the
side mounting-rail holes with the threaded holes in the front post of the rack. Align the bottom hole in
both the front-mounting brackets with a hole in each rack rail, making sure the chassis is level. See
Figure 33 on page 86.
85

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4650 Series and is the answer not in the manual?

Juniper EX4650 Series Specifications

General IconGeneral
CoolingFront-to-back or back-to-front airflow
Rack Units1U
MAC address table size288, 000 entries
Memory16 GB
Storage64 GB SSD
Power SupplyDual redundant, hot-swappable
Junos OSSupported
Jumbo frames9216 bytes
Operating temperature0°C to 40°C (32°F to 104°F)
Input voltageAC: 100-240V
FansHot-swappable, redundant
Operating humidity5% to 90% (non-condensing)
Ports48 x 10GbE SFP+/SFP28 ports 8 x 40GbE QSFP+/100GbE QSFP28 ports