Installation Programming Options
© JVA Technologies www.jva-fence.com JVA Z13 Manual
Key3 
0 None
+1 Siren codes
+2 Gate delay type
+4 4800 baud
+8 9600 baud
+16 Low Power Bite
+32 Bite to Low Power
9.5.16 
This option sets the time which must elapse before another alarm will sound
after the rst alarm has timed out (gone completely through its cycles without
being turned o).If an event occurs (such as a low fence voltage) which triggers
the siren, any other events which would otherwise trigger the siren (such as a
gate alarm) will be ignored while the siren is sounding and until after the Auto
Re-arm time has passed. A setting of 0 will disable Auto Re-arm.
If this time is set to less than the Siren O Time, the Energizer may re-arm in the
“O” time and the number of Siren Cycles will be reduced.
Key3 Time
0 0 Seconds
(Immediate)
1 30 Seconds
2 1 Minute
3 2 Minutes
4 3 Minutes
5 4 Minutes
6 5 Minutes
7 6 Minutes
8 7 Minutes
9 Disabled – Do not auto rearm