Standard Requirements for Security Electric Fences
Page 67 © JVA Technologies www.jva-fence.com
13.4.3
Pulsed conductors shall not be installed within the shaded zone shown in
Figure 8.
Prohibited Area for Pulse Conductors
NOTE: Where an electric security fence is planned to run close to a site
boundary, the relevant government authority should be consulted before