JVA Z13 Manual Page 7
Command Key1 Key2 Keys 3 and 4 Key5
Return Fence Alarm
Voltage For High
Power Mode
0 3 Enter the value in Hundreds of Volts #
Example: to set 3.8kV, use 38 for keys 3 and 4. Default is 30 (3.0kV)
Return Fence Alarm
Voltage For Low
Power Mode
0 5 Enter the value in Hundreds of Volts #
Example: to set 0.8V, use 08 for keys 3 and 4. Default is 05 0.5kV)
Bad/Missed Pulse
Count Before Alarm
Triggers
0 6 Enter the number of Missed Pulses #
Example: to set 14 counts, use 14 for keys 3 and 4. Default is 03
-
age (olts). Alarm Val-
ue Shown, Reduced
Power is 1V less
0 7 00 01 02 03 04 05 06 07 08 09 #
9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5
Siren On Time
(S=Seconds,
M=Minutes)
0 8 00 01 02 03 04 05 06 07 08 09 #
10S 30S 1M 2M 3M 4M 5M 20M 45M 130M

(S=Seconds,
M=Minutes)
0 9 00 01 02 03 04 05 06 07 08 09 #
10S 1M 2M 5M 10M 20M 30M 40M 50M 60M
Siren Cycles 1 0 00 01 02 03 04 05 06 07 08 09 #
0 1 2 3 4 5 6 7 8 9