Installation instructions Product description
Kaba c-lever k2evo702en-2012-05 11
3.4 Technical specifications
Terminal
Data transfer RFID
Body
Lever handle / plate Stainless steel
Operating environments
Protection class Outside (Standard): IP54
Outside (ES1): IP55
Inside: IP40
Temperature
-25° ... +70° C
1)
Humidity 0 ... 95% rH, non-condensing
Climate Not suitable for heavily corrosive atmospheres
(chlorine, ammonia)
Rooms Not to be used in environments where there is a risk
of explosion
Standards
Fire protection According to EN1634-1
EN179 According to test certificate:
0432 - BPR - 0061 (Kaba)
0432 - BPR - 0003 (BKS)
0432 - BPR - 0005 (Dorma)
ES1 protection class ES1 according to DIN18257, grade 2 according to
EN1906
WK2 according to B5351
Key:
1)
The temperature range depends on the battery manufacturer's specifications