23
3.6
3.5.8
3.6.2
3.6.3
3.6.4
3.6.5
3.6.7
3.6.6
3.7.1
3.7
Item Confirmation No. No. Cause Remedy RemarksProblem
Prob-
ability
Troubleshooting
1. Disassemble grinder
group according to 4.2.7;
2. Disassemble grinder
group according to 4.3.3
according to grinder
group explosive view
8810101002 replace or
repair damaged
components
YES - replace grinder group parts
Grinder group
damaged or end
of life
Coffee is to
soft, no
creama on
the top
3.5.8.3
3.5
Use
coffee
beans to
make
coffee
Refer to
3.5.3
LACK OF
POWDER
displays on
the screen
Not enough
coffee powder
YES - use Kalerm provided coffee
spoon, fill one full spoon of coffee
powder
NO - continue to 3.6.1.2
YES - open powder container
cover, clear coffee powder
channel
Coffee powder
channel is clogged
No coffee
comes out
from coffee
export
Coffee
temperatur
e is too low(
below
75°C)
Coffee
temperatur
e is too
high( more
than 75°C)
Coffee
volume is too
little (the
volume of
Espresso is
less than 25ml)
Coffee
volume is too
much (the
volume of
Espresso is
more than
100ml)
Coffee is
too soft, no
crema on
the top
Refer to
3.5.4
Refer to 3.5.5
Refer to 3.5.6
Refer to 3.5.7
Refer to 3.5.8
3.6.2.1
3.6.2.2
3.6.8
Use
coffee
powder
to make
coffee
The following should be repaired by dismatling the machine
Coffee machine
needs
descale(deposit
makes pipes inside
the machine
nearly clogged )
YES - descale
NO - continue to 3.7.1.2
Descale according to
5.2.2
Disassemble dispenser
valve 2W according to
4.2.12
YES - repair or replace dispenser
valve 2W, item: 8810101004
NO - continue to 3.7.1.3
YES - connect or replace leakage
position
NO - continue to 3.7.1.4
Dispenser valve
2W damaged and
does not work
(water dropped
to drip tray)
Inside pipe
connector
damaged or
dropped (water
leaks to the table)
The following should be repaired by dismatling the machine
3.7.1.1
3.7.1.2
3.7.1.3
The
process to
make hot
water
No water
comes out
from water
export
Solenoid valve
damaged
YES - replace solenoid valve,
Disassemble solenoid
valve according to
4.2.9
3.7.1.4