KEB COMBIVERT F5
Name: Basis
16.04.02
6
Section PageDate
© KEB Antriebstechnik, 2002
All rights reserved
Chapter
Functional DescriptionDigital In- and Outputs
The hysteresis, in reference to the adjusted values, defines the parameters
LE. 8...LE.15. Hysteresis 0 (LE.8) applies for comparison level 0; LE.9 for comparison
level 1 ... and so forth.
Default:
Frequency: 0,5 Hz
Voltage: 1 V
Analog values: 0,5 %
Current: 0,5 A
Temperature: 1 °C
LE.16 defines the hysteresis for the status constant-run and tripping frequencies for
the DC-brake.
Hysteresis 0...7
LE. 8...LE.15
Frequency hysteresis LE.16
Response to warning signals
Pn.8, Pn.10, Pn.12, Pn.14,
Pn.16
These parameters determine the behaviour of the inverter in case of warning signals.
To learn more about the adjustment possibilities as well as the performance of the
appropriate drive please refer to Chapter 6.7 „Protective functions“.
Level 0...7
LE.0...LE.7
These parameters defines the level of the switching conditions. Level 0 (LE.0) applies
for switching condition 0; LE.1 for switching condition 1 ... and so forth.
Setting range: -30000,00...30000,00
Step: 0,01
Default: see parameter table
Bei der Vorgabe in Inkrementen entspricht ein Inkrement gleich 0,01.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 BASIC and is the answer not in the manual?

KEB COMBIVERT F5 BASIC Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5 BASIC
CategoryIndustrial Electrical
LanguageEnglish

Related product manuals