EasyManua.ls Logo

KEB COMBIVERT F5 BASIC - Page 153

KEB COMBIVERT F5 BASIC
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
43
KEB COMBIVERT F5-G / B
Name: Basis
06.02.02
6
© KEB Antriebstechnik, 2002
All rights reserved
Functional DescriptionSet Value and Ramp Adjustment
Section PageDate Chapter
6.4.1 Summary
Description
6.4 Setpoint-, Rotation- and Ramp Adjustment
Fig. 6.4.1 Principle of set value and ramp adjustment
The setpoint values of the KEB COMBIVERT F5 can be preadjusted analog as well
as digital. The AUX-function adds or multiplies an analog setpoint to/with other setpoint
settings.
The setpoint and rotation selection links the different setpoint sources with the possible
sources of rotation direction. The signal thus obtained is used for further setpoint
calculation.
Only after interrogation of the absolute setpoint limits, all the data that is required for
the ramp calculation is available.
Rotation
selection
Setpoint limits
Setpoint computation
Ramp generator
Control processor
Display set frequency /
-speed before ramp
Display actual
frequency
Fixed
frequencies
Setpoint
selection
Limiter
Display ramp output
frequency

Table of Contents