dr.0 0600h ✔✔- 0,0 A 710,0 A 0,1 A P-ID*) max. 25,5 A at B-housing
dr.1 0601h ✔✔- 0 rpm 64000 rpm 1 rpm P-ID*) -
dr.2 0602h ✔✔- 120 V 500 V 1 V P-ID*) -
dr.3 0603h ✔✔- 0,35 kW 400,00 kW 0,01 kW P-ID*) -
dr.4 0604h ✔✔- 0,50 1,00 0,01 P-ID*) -
dr.5 0605h ✔✔- 0,0 Hz 1600,0 Hz 0,1 Hz P-ID*) -
dr.6 0606h ✔✔- 0,000 Ohm 50,000 Ohm 0,001 Ohm P-ID*) 50 Ohm start automatic determitation
dr.9 0609h ✔✔- 0,5 4,0 0,1 2,5 -
Fr.10 090Ah ✔✔✔ 3313-