36
Adjustment range:  -10.0...10.0 %
Resolution:   0.1 %
Factory setting:  0.2 %
AN1 Zero point 
hysteresis
Noise coupled capacitively or inductively  into the analog signal wires can 
cause the motor to drift in spite of the filtering of the analog input. The zero 
point hysteresis can be used to suppress this noise and therefore prevent 
the motor from drifting.
 
With parameter CP.36 the analog signal AN1 (X2.1,X2.2)  can be masked 
in the range of  0...±10.0%  (0...±1.00V). The adjusted value is valid for both 
directions of rotation.  
If a negative percentage value is adjusted then the hysteresis is not only 
effective at the zero point but also around the actual set value. This means 
changes to the set value during constant operation are accepted only when 
the change is larger than the adjusted hysteresis.
Special Adjustments