Parameter sets
© KEB, 2015-07 COMBIVERT R6-N Page3.7 - 9
3
10
ID IB I3 I2 I1 Set Set
0
1
2
3
4
5
I1
I2
I3
IB
ID
Set
Set
Set
Set
Set
Set
Fr.02 = 3 4
0 0 0 0 0 0 0
0 0 0 0 1 1 1
0 0 0 2 0 2 2
0 0 3 0 0 3 3
0 4 0 0 0 4 4
5 0 0 0 0 5 5
5 0 3 0 0 3 5
5 0 3 0 1 1 5
Reset set input selection (fr.11)
ParameterFr.11denesaninput,independent of the actual parameter set it can be switched in parameter set
0. This function is only active at Fr.02 = 2...4
- with static input assignment the inverter remains in set 0 as long as the input is set.
- with edge-triggered inputs set 0 is activated with the 1st edge. With the 2 nd edge the set activated by
the other inputs is selected again.
3.7.7 Locking of parameter sets
Fr.03 Parameter set lock
Parameter sets, which shall not be selected, can be locked with Fr.03. If one of the locked sets is selected, the
adjusted response in Pn.18isexecuted(default:setsourceerrorE.SEt).
Value Locked set Example (set 2 and 5 locked)
1 0 -
2 1 -
4 2 4
8 3 -
16 4 -
32 5 32
64 6 -
128 7 -
Sum:36
3.7.8 Parameter set ON/OFF delay (Fr.05, Fr.06)