Table of Contents
i
1 Performance Verification
1.1 Introduction.......................................................................................................................................................... 1-1
1.2 Environmental conditions .................................................................................................................................... 1-1
1.3 Warm-up period ...................................................................................................................................................1-1
1.4 Line power ...........................................................................................................................................................1-1
1.5 Recommended test equipment .............................................................................................................................1-2
1.6 Verification limits ................................................................................................................................................ 1-2
1.7 Restoring default conditions ................................................................................................................................1-2
1.8 Verification procedures........................................................................................................................................1-4
1.8.1 DC volts verification....................................................................................................................................1-4
1.8.2 AC volts verification....................................................................................................................................1-5
1.8.3 DC current verification .............................................................................................................................. 1-10
1.8.4 AC current verification .............................................................................................................................. 1-11
1.8.5 Resistance verification ............................................................................................................................... 1-13
1.8.6 Frequency accuracy verification ................................................................................................................1-16
1.8.7 Temperature reading checks ......................................................................................................................1-17
2Calibration
2.1 Introduction.......................................................................................................................................................... 2-1
2.2 Environmental conditions .................................................................................................................................... 2-1
2.3 Warm-up period ...................................................................................................................................................2-2
2.4 Line power ...........................................................................................................................................................2-2
2.5 Calibration lock....................................................................................................................................................2-2
2.5.1 Comprehensive calibration lock...................................................................................................................2-2
2.5.2 Low-level calibration lock ...........................................................................................................................2-2
2.5.3 IEEE-488 bus calibration lock status........................................................................................................... 2-2
2.6 IEEE-488 bus calibration commands and program ............................................................................................. 2-2
2.6.1 Calibration commands .................................................................................................................................2-2
2.6.2 Required order of command execution........................................................................................................2-4
2.6.3 Example calibration command program......................................................................................................2-4
2.7 Calibration errors .................................................................................................................................................2-5

Table of Contents

Other manuals for Keithley 2001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2001 and is the answer not in the manual?

Keithley 2001 Specifications

General IconGeneral
Model2001
CategoryMultimeter
ManufacturerKeithley
TypeDigital Multimeter
Digits of Resolution7.5
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
Frequency Range3 Hz to 500 kHz
ConnectivityGPIB, RS-232
DisplayVFD
Resistance Accuracy0.008% + 2.0 mΩ
Frequency Accuracy±0.01%
DC Current Range10 μA to 3 A
AC Current Range10 μA to 3 A
Power Supply100 V to 240 V AC, 45 Hz to 66 Hz