IEEE-488 Reference
3-118
Effects of positive transitions on the Measurement Event Register:
Positive transition effect on
Measurement event Measurement Event Register
Reading overflow Sets B0 when reading exceeds range limits.
Low limit 1 Sets B1 when reading is less than the low limit 1 setting.
High limit 1 Sets B2 when reading is greater than the low limit 1 setting.
Low limit 2 Sets B3 when reading is less than the low limit 2 setting.
High limit 2 Sets B4 when reading is greater than the high limit 2 setting.
Reading available Sets B5 after a reading is taken and processed.
Reading underflow Sets B6 when an ohms reading is below the lower range limit.
Buffer available Sets B7 when the trace buffer has at least two readings.
Buffer half full Sets B8 when the trace buffer becomes half full.
Buffer full Sets B9 when the trace buffer becomes full.
Sequence reading available Sets B10 when an Alternating Polarity test sequence reading
becomes available.
Buffer pretriggered Sets B11 when the trace buffer pretrigger event occurs.
Out of Limits Sets B12 when a noise spike occurs.
Fixture lid closed Sets B13 when fixture lid is closed.
V-source compliance Sets B14 when V-source goes in compliance.
F
igure 3-34
M
easurement Transition Filter
RAV
B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0
(2 )
9
(2 )
8
(2 )
7
(2 )
5
(2 )
4
(2 )
3
(2 )
2
(2 )
1
(2 )
0
32
0/1
Bit Position
Event
Decimal Weighting
Value
Value : 1 = Enable Positive Transition
0 = Disable Positive Transition
LL1
2
0/1
Events : VSC = V-Source Compliance
FLC = Fixture Lid Closed
OL = Out of Limits
BPT = Buffer Pretriggered
SRA = Sequence Reading Available
BFL = Buffer Full
BHF = Buffer Half Full
BAV = Buffer Available
RUF = Reading Underflow
RAV = Reading Available
HL2 = High Limit 2
LL2 = Low Limit 2
HL1 = High Limit 1
LL1 = Low Limit 1
ROF = Reading Overflow
BFL HL2 HL1 ROF
512 16 4 1
0/1 0/1 0/1 0/1
BHF BAV LL2
256 128 8
0/1 0/1 0/1
BPT
B11
(2 )
11
2048
0/1
B14 B13 B12
0/1
4096
0/1
B15
(2 )
12
VSC OL RUF
16384
(2 )
14
(2 )
6
256
0/1
A) Positive Transition (PTR) Register
RAV
B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0
(2 )
9
(2 )
8
(2 )
7
(2 )
5
(2 )
4
(2 )
3
(2 )
2
(2 )
1
(2 )
0
32
0/1
Bit Position
Event
Decimal Weighting
Value
Value : 1 = Enable Negative Transition
0 = Disable Negative Transition
LL1
2
0/1
Events : VSC = V-Source Compliance
FLC = Fixture Lid Closed
OL = Out of Limits
BPT = Buffer Pretriggered
SRA = Sequence Reading Available
BFL = Buffer Full
BHF = Buffer Half Full
BAV = Buffer Available
RUF = Reading Underflow
RAV = Reading Available
HL2 = High Limit 2
LL2 = Low Limit 2
HL1 = High Limit 1
LL1 = Low Limit 1
ROF = Reading Overflow
BFL HL2 HL1 ROF
512 16 4 1
0/1 0/1 0/1 0/1
BHF BAV LL2
256 128 8
0/1 0/1 0/1
BPT
B11
(2 )
11
2048
0/1
B14 B13 B12
0/1
4096
0/1
B15
(2 )
12
VSC OL RUF
16384
(2 )
14
(2 )
6
256
0/1
A) Negative Transition (NTR) Register
SRA
(2 )
10
1024
0/1
SRA
(2 )
10
1024
0/1
FLC
8192
(2 )
13
0/1
FLC
8192
(2 )
13
0/1

Table of Contents

Other manuals for Keithley 6517A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 6517A and is the answer not in the manual?

Keithley 6517A Specifications

General IconGeneral
BrandKeithley
Model6517A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals